Restrictions
A direct Serial run from the PMS terminal to the PMS system is required
PMS module required
System must interface with Micros 2700 Serial Interface
Hyper terminal should be used to test the communication between the Focus and the PMS system
Process:
Step 1: Ensure a direct serial cable is run from Focus PMS processing station to PMS system
Note: If distance is too far for Serial cable run, Serial to Cat 5 adapters can be used Step 2: Configure Focus
- Navigate to Miscellaneous > General > CreditCard/PMS/GiftCard/Loyalty > Property Management Options
- Port = Specify the Port used to communicate with the property management system
- Baud = Set the Baud Rate as dictated by the property management system
- Parity = Specify the Parity as dictated by the property management system
- Data Bits = Specify the Data Bits as dictated by the property management system
- Stop Bits = Specify the Stop Bits as dictated by the property management system
Step 3: Configure Payment
- Type = Account
- Options=
- Tip Required
- Over-Tender Equals Tip
- Print Check When Closed
- Post
- Edit Tips Open Drawer
- Field Options
- Require Account
- Depending on PMS system you may have to select Prompt for Folio
- PMS Option - Specified by PMS if Account is required
Comments